{"id":310,"date":"2025-09-01T18:43:03","date_gmt":"2025-09-01T18:43:03","guid":{"rendered":"https:\/\/witdd.com\/?page_id=310"},"modified":"2025-09-01T18:43:04","modified_gmt":"2025-09-01T18:43:04","slug":"portable-clean-agent-ce-lpcb-approved","status":"publish","type":"page","link":"https:\/\/witdd.com\/index.php\/portable-clean-agent-ce-lpcb-approved\/","title":{"rendered":"Portable Clean Agent (CE \/ LPCB Approved)"},"content":{"rendered":"\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"700\" height=\"600\" src=\"https:\/\/witdd.com\/wp-content\/uploads\/2025\/09\/portable-clean-agent-_ce-lpcb-approved.jpg\" alt=\"\" class=\"wp-image-311\" srcset=\"https:\/\/witdd.com\/wp-content\/uploads\/2025\/09\/portable-clean-agent-_ce-lpcb-approved.jpg 700w, https:\/\/witdd.com\/wp-content\/uploads\/2025\/09\/portable-clean-agent-_ce-lpcb-approved-300x257.jpg 300w\" sizes=\"(max-width: 700px) 100vw, 700px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>FEATURES<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>LPCB Approved for different capacity of extinguishers.<\/li>\n\n\n\n<li>Cylinders compliance to council directive 2014\/68\/EU(PED). Certified by BSI (2797)<\/li>\n\n\n\n<li>Safe for People: It is indented for use as a streaming agent providing a gas concentration sufficient to extinguish a fire.It is safe for use in occupied spaces.<\/li>\n\n\n\n<li>Safe for Assets: It is electrically non conductive, noncorrosive, and free of residue. As a gaseous agent, it targets the flame and extinguishes the fire. Operations can resume quickly, particularly if early detection methods are in use.<\/li>\n\n\n\n<li>Safe for the Environment: It does not contain chlorineor bromine, and has zero ozone depletion potential like many fluoride based gases, HFC-236fa has some global warming potential.<\/li>\n\n\n\n<li>Clean Agent Hexafluoropropane Gas based Extinguishing Agent capable of fighting class A, B, C and Electrical fires effectively.<\/li>\n\n\n\n<li>Low in toxicity.<\/li>\n\n\n\n<li>Standard compliance BSEN3.<\/li>\n\n\n\n<li>High Performance Extinguishing Agent.<\/li>\n\n\n\n<li>High Quality external Polyester Paint to avoid corrosion<\/li>\n\n\n\n<li>Brass Nickel plated head valve with simple squeeze operation.<\/li>\n\n\n\n<li>Rechargeable &amp; easy to service<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>SPECIFICATIONS<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Model Number<\/td><td class=\"has-text-align-center\" data-align=\"center\">NHFC-4<\/td><td class=\"has-text-align-center\" data-align=\"center\">NHFC-6<\/td><td class=\"has-text-align-center\" data-align=\"center\">NHFC-9<\/td><td class=\"has-text-align-center\" data-align=\"center\">NHFC-12<\/td><\/tr><tr><td>Extinguisher Capacity<\/td><td class=\"has-text-align-center\" data-align=\"center\">4 kg<\/td><td class=\"has-text-align-center\" data-align=\"center\">6 kg<\/td><td class=\"has-text-align-center\" data-align=\"center\">9 kg<\/td><td class=\"has-text-align-center\" data-align=\"center\">12 kg<\/td><\/tr><tr><td>Propellant<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"4\">95% Nitrogen + 5% Helium<\/td><\/tr><tr><td>Fire Rating<\/td><td class=\"has-text-align-center\" data-align=\"center\">34B<\/td><td class=\"has-text-align-center\" data-align=\"center\">5A 55B<\/td><td class=\"has-text-align-center\" data-align=\"center\">8A 70B<\/td><td class=\"has-text-align-center\" data-align=\"center\">13A 70B<\/td><\/tr><tr><td>Working Pressure<\/td><td class=\"has-text-align-center\" data-align=\"center\">15 bar<\/td><td class=\"has-text-align-center\" data-align=\"center\">15 bar<\/td><td class=\"has-text-align-center\" data-align=\"center\">15 bar<\/td><td class=\"has-text-align-center\" data-align=\"center\">15 bar<\/td><\/tr><tr><td>Maximum Operating Pressure<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"4\">21 bar @ 60\u00baC<\/td><\/tr><tr><td>Test Pressure<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"4\">30 bar<\/td><\/tr><tr><td>Total Weight<\/td><td class=\"has-text-align-center\" data-align=\"center\">7.3 kg<\/td><td class=\"has-text-align-center\" data-align=\"center\">10.3 kg<\/td><td class=\"has-text-align-center\" data-align=\"center\">13.8 kg<\/td><td class=\"has-text-align-center\" data-align=\"center\">17.9 kg<\/td><\/tr><tr><td>Range of Discharge<\/td><td class=\"has-text-align-center\" data-align=\"center\">4 &#8211; 5 m<\/td><td class=\"has-text-align-center\" data-align=\"center\">4 &#8211; 5 m<\/td><td class=\"has-text-align-center\" data-align=\"center\">4 &#8211; 5 m<\/td><td class=\"has-text-align-center\" data-align=\"center\">4 &#8211; 5 m<\/td><\/tr><tr><td>Duration of Discharge<\/td><td class=\"has-text-align-center\" data-align=\"center\">14 &#8211; 16 sec.<\/td><td class=\"has-text-align-center\" data-align=\"center\">20 &#8211; 22 sec.<\/td><td class=\"has-text-align-center\" data-align=\"center\">23 &#8211; 26 sec.<\/td><td class=\"has-text-align-center\" data-align=\"center\">38 &#8211; 40 sec.<\/td><\/tr><tr><td>Operating Temperature<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"4\">-20\u00baC to +60\u00ba C<\/td><\/tr><tr><td>Cylinder Material<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"4\">CRCA Steel Sheet<\/td><\/tr><tr><td>Hose Length with Nozzle<\/td><td class=\"has-text-align-center\" data-align=\"center\">535 mm<\/td><td class=\"has-text-align-center\" data-align=\"center\">625 mm<\/td><td class=\"has-text-align-center\" data-align=\"center\">595 mm<\/td><td class=\"has-text-align-center\" data-align=\"center\">690 mm<\/td><\/tr><tr><td>Height x Diameter (mm)<\/td><td class=\"has-text-align-center\" data-align=\"center\">425 x 150<\/td><td class=\"has-text-align-center\" data-align=\"center\">527 x 150<\/td><td class=\"has-text-align-center\" data-align=\"center\">530 x 184<\/td><td class=\"has-text-align-center\" data-align=\"center\">620 x 184<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>RESOURCES<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>CE Certificate<\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/naffco.com\/media\/lof\/assets\/fire-fighting\/fire-extinguishers\/portable-extinguisher\/clean-agent\/portable-clean-agent-kitemark-approved\/product-approval-certificate-CE-67248.pdf\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Download<\/strong><\/a><\/td><\/tr><tr><td>LPCB Approval Certificate<\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/naffco.com\/media\/lof\/assets\/fire-fighting\/fire-extinguishers\/portable-extinguisher\/clean-agent\/portable-clean-agent-kitemark-approved\/product-approval-certificate-LPCB.pdf\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Download<\/strong><\/a><\/td><\/tr><tr><td>Technical Datasheet<\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/naffco.com\/media\/lof\/assets\/fire-fighting\/fire-extinguishers\/portable-extinguisher\/clean-agent\/portable-clean-agent-kitemark-approved\/technical-data-sheet.pdf\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Download<\/strong><\/a><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"4\"><strong>Technical Drawings<\/strong><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/naffco.com\/media\/lof\/assets\/fire-fighting\/fire-extinguishers\/portable-extinguisher\/clean-agent\/portable-clean-agent-kitemark-approved\/NHFC-4.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">NHFC 4<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/naffco.com\/media\/lof\/assets\/fire-fighting\/fire-extinguishers\/portable-extinguisher\/clean-agent\/portable-clean-agent-kitemark-approved\/NHFC-6.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">NHFC 6<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/naffco.com\/media\/lof\/assets\/fire-fighting\/fire-extinguishers\/portable-extinguisher\/clean-agent\/portable-clean-agent-kitemark-approved\/NHFC-9.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">NHFC 9<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/naffco.com\/media\/lof\/assets\/fire-fighting\/fire-extinguishers\/portable-extinguisher\/clean-agent\/portable-clean-agent-kitemark-approved\/NHFC-12.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">NHFC 12<\/a><\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>FEATURES SPECIFICATIONS Model Number NHFC-4 NHFC-6 NHFC-9 NHFC-12 Extinguisher Capacity 4 kg 6 kg 9 kg 12 kg Propellant 95% Nitrogen + 5% Helium Fire Rating 34B 5A 55B 8A 70B 13A 70B Working Pressure 15 bar 15 bar 15 bar 15 bar Maximum Operating Pressure 21 bar @ 60\u00baC Test Pressure 30 bar Total &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/witdd.com\/index.php\/portable-clean-agent-ce-lpcb-approved\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;Portable Clean Agent (CE \/ LPCB Approved)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"pagelayer_contact_templates":[],"_pagelayer_content":"","footnotes":""},"class_list":["post-310","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/witdd.com\/index.php\/wp-json\/wp\/v2\/pages\/310","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/witdd.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/witdd.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/witdd.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/witdd.com\/index.php\/wp-json\/wp\/v2\/comments?post=310"}],"version-history":[{"count":1,"href":"https:\/\/witdd.com\/index.php\/wp-json\/wp\/v2\/pages\/310\/revisions"}],"predecessor-version":[{"id":312,"href":"https:\/\/witdd.com\/index.php\/wp-json\/wp\/v2\/pages\/310\/revisions\/312"}],"wp:attachment":[{"href":"https:\/\/witdd.com\/index.php\/wp-json\/wp\/v2\/media?parent=310"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}